IKO Bearings end of the installation, in order to check the installation is correct, the operation check. Small mechanical hand rotation, to determine whether the rotation smooth. Inspection items nick, indentation caused by dysfunctional torque instability, arising due to poor installation, mount processing bad due to the clearance is too small, installation errors, and seal friction torque and so on. If there is no exception, you can start the power operation.
Power operation, start from no-load low-speed, slowly increased to the conditions stipulated in the rated operation. Test run to check the matters, whether there is abnormal sound, flange bearing temperature changes, lubricant leakage or discoloration. If abnormal, should be immediately discontinued operation, check the mechanical, if necessary, to remove the bearing check.
IKO bearing temperature, and can be speculated that under the external temperature of the bearing. However, the use of hole directly measuring the temperature of the bearing outer ring is more accurate. Flange bearing temperature gradually increased from the operation, usually 1 to 2 hours after temperature stabilization. If the bearing is bad installation, the temperature will soar, and abnormal high temperature. The reason lubricant such as excessive bearing clearance is too small, poor installation, and sealing devices friction is too large.
(1) to maintain a clean bearing lubrication
IKO bearings before the inspection should first clean the flange bearing surface, and then carefully check the bearing oil seal and the surrounding parts have shown undesirable symptoms, be sure to change out the bad oil seal will cause damage, the bearing cloud like normal equipment downtime.
Note that the coverage of exposed bearing
Do not let the check bearing bearings exposed to the environment of contaminants or moisture. If the interruption of work should be based on the greaseproof paper of plastic sheeting or similar material to cover once the machine. Cleaning the exposed bearings without disassembling the case may perform a check, coated with a petroleum solvent cleaning to coating with the brush, then dry with a lint cloth or compressed air (be careful not to bearing assemblies starting rotation). Kind of probe used by a small mirror and similar dentist to check the orbital plane of the flange bearing retainer and beads. Not cleaning encryption cover or dust IKO bearings; wipe the external surface can be. If the bearing was damage to the circumstances that need replacing. Replacement of bearing much more economical due to the array bearing damage selected as the sudden stop loss in the regular shutdown maintenance period.
Check bearing lubricant
The lubricant is very important not only for the bearing, but also for all of IKO bearings. Note, however, the bearing should not add too much grease. Then is to replace the bearing lubricant. The use of oil lubricated bearings diarrhea in addition to the old oil, if you can, it should be re-poured fresh oil and the machine a few minutes at low speed rotation. As much as possible so that the oil to the collection of residual contaminants, and then diarrhea among these oil. The use of grease lubricated bearings in the replacement of grease used Joe in addition to the device should be avoided with a cotton material come into contact with any part of the flanged. Because these residual fibers may be wedged in between the rolling elements and cause damage, especially bearing applications should pay more attention to this problem.
Other News:
IKO flange bearing operation when the heat of an inspection and maintenance
Beryllium copper heat treatment should be noted that some of the issues
Bearing circle, the outer diameter of the save way
United States: Greece off Europe the possibility of still higher than 50%
Taiwan steel cancels investment in Australia coal mine plan
To the inventory of steel weakening of the seasonal decline of steel prices or o
Steel market expected to demand
U.S. Steel said the surge in steel pipe imports threaten local market