Company Name:
Lishui Huanqiu Bearing Trading Co., Ltd.
Company Address:
No.11 Shiting Road, Shuige Industrial Zone,Lishui, Zhejiang,China
Contact Person: William
Email: admin@tradebearings.com
Homepage: www.asiabearings.com
Bearing B2B: www.tradebearings.com
1, first start the static pressure devices oil pump, one minute until the pressure reaches the design requirements, the pressure oil to the spindle or table float, and then start the machine tool dynamic change.
2, the static pressure device in operation, are not allowed to stop oil supply. Only in the spindle or table completely stop running, to stop the oil.
3, the static pressure oil system failure suddenly interrupted oil supply, it is necessary to immediately stop the static pressure device operation.
Often observe the oil pressure gauge on the tank static pressure and static pressure
bearings or hydrostatic guide way, to maintain the stability of the oil pressure. Such as the hydraulic instability or makes unusual noise and other anomalies, we must immediately stop
and check, troubleshoot, and then continue to work.
5, pay attention to check the static pressure inside the tank oil level dropped, the oil level below the tank height two-thirds, must be added to fuel.
6, the double shift system of machine tools, hydrostatic tank annually clean oil first, the static pressure device apart and wash once a year.